BARNES GROUP INC BOWMAN DISTRIBUTION DIV -- BATTERY TERMINAL PROTECTOR -- 6850-01-288-3054
=====================  Product Identification  =====================

Product ID:BATTERY TERMINAL PROTECTOR
MSDS Date:01/22/1990
FSC:6850
NIIN:01-288-3054
=== Responsible Party ===
Company Name:BARNES GROUP INC BOWMAN DISTRIBUTION DIV
Address:850 E 72ND ST
Box:6908
City:CLEVELAND
State:OH
ZIP:44101
Country:US
Info Phone Num:216-391-7200 / FAX 216-391-1121
Emergency Phone Num:216-391-7200
CAGE:05573
=== Contractor Identification ===
Company Name:BOWMAN DISTRIBUTION, BARNES GROUP INC
Address:1301 EAST 9TH ST, SUITE 700
Box:City:CLEVELAND
State:OH
ZIP:44114-1824
Country:US
Phone:216-416-7200
CAGE:05573

=============  Composition/Information on Ingredients  =============

Ingred Name:XYLENES (O-,M-,P- ISOMERS)	(SARA III)
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: 5-10%
OSHA PEL:100 PPM/150 STEL
ACGIH TLV:100 PPM/150STEL;9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:METHYLENE CHLORIDE	(SARA III)
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: 10-15%
OSHA PEL:500 PPM/C,1000; Z2
ACGIH TLV:50 PPM, A2; 9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:PROPELLANT (PROPANE/ISOBUTANE/N-BUTANE)
Fraction by Wt: 23%

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CAN CAUSE NASAL AND RESPIRATORY
    IRRITATION.  CHRONIC: PERMANENT BRAIN AND NERVOUS SYSTEM DAMAGEHAS
    BEEN REPORTED. OVEREXPOSURE TO THESSE CHEMICALS HAS BEEN FOUND TO
    CAUSE DAMAGE TO LUNGS, HEART , LIVER, KIDNEYS AND SPLEEN IN
    LABORATORY ANIMALS. LIVER ABNORMALITIES HAVE BEEN FOUND IN HUMANS.
Explanation of Carcinogenicity:METHYLENE CHLORIDE IS REPORTED TO CAUSE
    CANCER IN LABORATORY ANIMALS.
Effects of
    Overexposure:DIZZINESS,WEAKNESS,FATIGUE,NAUSEA,HEADACHE,POSSIBLE
    UNCONSCIOUSNESS & EVEN ASPHYSXIATION.

=======================  First Aid Measures  =======================

First Aid:IF AFFECTED,REMOVE INDIVIDUAL TO FRESH AIR. IF BREATHING IS
    DIFFICULT,ADMINISTER OXYGEN.IF BREATHING HAS STOPPED,GIVE
    ARTIFICIAL RESPIRATION. KEEP PERSON WARM,QUIET & GET MEDICAL
    ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point Method:CC
Flash Point:-0F,-18C
Lower Limits:1.0
Extinguishing Media:CO*2,DRY CHEMICAL, OR ALCOHOL FOAM.
Fire Fighting Procedures:WATER SPRAY MAY BE INEFFECTIVE;WATER MAY BE
    USED TO COOL CLOSED CONTAINERS TO PREVENT PRESSURE BUILD-UP &
    POSSIBLE AUTOIGNITION OR EXPLOSION,EXPOSED TO HIGH HEA
Unusual Fire/Explosion Hazard:VAPORS ARE HEAVIER THAN AIR & MAY TRAVEL
    ALONG THE GROUND & IGNITED BY PILOT LIGHTS,FLAMES,ETC.

==================  Accidental Release Measures  ==================

Spill Release Procedures:ABSORB LIQUID ON PAPER,VERMICULITE,FLOOR
    ABSORBENT OR OTHER ABSORBENT MATERIAL & TRANSFER TO A CLOSED
    CONTAINER. ELIMINATE ALL IGNITION SOURCES.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT STORE IN AREAS ABOVE 120F OR IN
    DIRECT SUNLIGHT OR NEAR HEAT OR OPEN FLAMES.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:WHEN TLV EXCEEDED,USE NIOSH/MSHA JOINTLY
    APPROVED SELF-CONTAINED BREATHING APPARATUS WITH A FULL PIECE
    OPERATED IN PRESSURE DEMAND.
Ventilation:LOCAL EXHAUST.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:CHEMICAL GOGGLES.
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

HCC:V3
Boiling Pt:B.P. Text:104-281F
Vapor Pres:340
Spec Gravity:0.9
Appearance and Odor:LIQUID,RED GREASE,SOLVENT ODOR.
Percent Volatiles by Volume:80-85

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT,SPARKS OR OPEN FLAMES.
Hazardous Decomposition Products:NONE STATED.

====================  Disposal Considerations  ====================

Waste Disposal Methods:MATERIAL COLLECTED ON ABSORBENT MATERIAL MAY BE
    DEPOSITED IN A POSTED TOXIC SUBSTANCE LANDFILL IN ACCORDANCE WITH
    LOCAL,STATE & FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.